Bosh sahifa / Mahsulotlar / Agent ES1098

Agent ES1098 Oltin va qimmatbaho metallarni ajratish

Tanlangan ruda va qayta ishlash xomashyosini alohida baholash

Ishlab chiqarish ko‘lamini oshirishdan oldin tanlangan ruda va ikkilamchi xomashyodan qimmatbaho metallarni ajratish uchun Agent ES1098 ni baholang. Katalog xomashyoga mos sinovlar uchun heap, vat va CIL/CIP jarayonlarini ko‘rsatadi; yakuniy ish sharoitlari va keyingi ajratish usuli reprezentativ namunalar sinovi natijalariga ko‘ra tanlanadi.

Katalogni yuklab olish · PDFMahsulot bo‘yicha so‘rov yuborish

Loyihani baholash uchun yordam

  • Ko‘lamni oshirishdan oldin reprezentativ namunalarni sinash.
  • Eritmaga o‘tkazish, ajratish va eritmalarni boshqarish jarayonlarini ko‘rib chiqish.
  • ES1098 uchun boshlang‘ich ma’lumotlar va konsentratsiya nazorati.
  • Texnik hujjatlar va loyihaga mos ishlash taklifi.

Baholanadigan qo‘llanish sohalari

  • Xomashyoga mos sinovlardan keyin tanlangan rudalar
  • Tayyorlangan elektron chiqindi xomashyosi
  • Tayyorlangan avtomobil katalizatori materiallari
  • Tayyorlangan quyosh paneli materiallari

Katalog ma’lumotlari ES1098 bilan nazoratli sinovlar uchun boshlang‘ich nuqtalardir; ular natija kafolati yoki barcha loyihalar uchun bir xil ish sharoitlari emas. Amaldagi SDS, obyektga xos HSE baholashi va mahalliy talablar hisobga olinadi.

Texnik ma’lumotlar

Texnik xususiyatlar va qo‘llash tartibi ingliz tilida qoladi. Asl PDF kataloglari o‘zgartirilmaydi.

Agent ES1098 is available for controlled evaluation in selected precious-metal ore and recycling projects. Final conditions must be defined from representative feed testwork.

Controlled technical references

Product form Light-grey to light-brown granules or powder
Dosage basis Per tonne of water solution, not dry ore tonnage
Many oxide, semi-oxide and quartz-vein ores around 3–8 g/t Au 0.5–1.5 kg/t water solution as a test starting range
Sulphide-dominant feeds 2–5 kg/t water solution as a test starting range
Ore-test pH reference pH 11.0–11.5; when using lime, do not exceed pH 12

Concentration control

The catalogue references Agent A and Indicator B for titration-based monitoring. Replenishment is calculated from the difference between target and measured concentration multiplied by the total solution volume. Use the current controlled procedure and project analytical plan. Catalogue worked examples for ES1098 only (water-solution basis): for the stated 5 g/t ore example, 1,500 L water (1.5 tonnes) at the selected 0.65 kg ES1098 per tonne of water gives 0.65 × 1.5 = 0.975 kg ES1098. For a 100 m³ solution pool, a target of 1.2‰ and measured concentration of 0.7‰ give (1.2 − 0.7) × 100 = 50 kg ES1098 replenishment under the manual’s per-mille convention. These examples use the catalogue’s stated assumptions, not universal doses; verify by representative testing and do not apply them to ES1099.

Process and recovery context

Heap, vat and agitated CIL/CIP contexts may be evaluated. Activated carbon, resin, zinc cementation or selected electrowinning routes are chosen from solution composition and test results.

Safety and handling

Use the current SDS, appropriate PPE, site controls, controlled storage and local requirements. Catalogue values do not replace project risk assessment.

Document control: This page follows the September 2026 ES1098 & ES1099 Product & Application Overview. Values are reference starting points only. Final conditions require representative testing, the current SDS, project HSE controls and local requirements. Open the original catalogue.

ES1098 loyihasini dastlabki baholash uchun xomashyo tavsifi, tahlil natijalari, quvvat, amaldagi jarayon va ajratish maqsadini yuboring.

Ingliz tilidagi texnik ma’lumotlarni o‘qish · Ingliz tilidagi asl PDF fayl

✉↑